Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Biosci. j. (Online) ; 38: e38035, Jan.-Dec. 2022. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1395457

RESUMEN

This study aimed to investigate the effect of two ceramic primers on the microshear bond strength (µSBS) of yttria-stabilized zirconia (Y-TZP) to two types of self-adhesive resin cement and one BisGMA-based resin cement. Zirconia specimens were sandblasted with 27-µm aluminum oxide and composite cylinders were cemented with resin cement with or without the prior use of ceramic primers. Nine groups (n=12) were randomly distributed according to the cement (self-adhesive RelyX U200/3M ESPE, self-adhesive Maxcem Elite/Kerr, and BisGMA-based dual-cure RelyX ARC/3M ESPE) and ceramic primer (Z-Primer Plus/Bisco and Porcelain Liner M/Sun Medical Co.). After luting, the specimens were stored in distilled water at 37°C for 24 hours and then submitted to the µSBS test. The data were analyzed with two-way ANOVA followed by the Scheffe post hoc test (p<0.05). There were significant differences between RelyX U200 and other groups. There were also significant differences between the RelyX U200 group without ceramic primer and other groups without ceramic primers (p<0.05). Self-adhesive resin cement (RelyX U200 and MaxCem) presented higher microshear bond strength (6.17 and 2.32 MPa) than the conventional resin cement (RelyX ARC) when a porcelain primer was not used (0.43 MPa). When using Porcelain Liner M, the results of RelyX ARC (2.94 MPa) were equivalent to the results of self-adhesive cement (3.93 and 2.11 MPa). When using Z-Prime Plus, the results of MaxCem (5.36 MPa) were lower than those of RelyX U200 (9.59 MPa) but equivalent to those of RelyX ARC (6.07 MPa). When using the RelyX ARC, the use of both ceramic primers improved bond strength to zirconia. When using self-adhesive resin cement, Z-Prime Plus improved microshear bond strength values. It can be concluded that, after 24 hours, the highest µSBS results were obtained when using Z-Prime Plus and RelyX U200 self-adhesive cement.


Asunto(s)
Cerámica , Prótesis Dental , Resistencia al Corte
2.
Biosci. j. (Online) ; 36(5): 1785-1793, 01-09-2020. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1147935

RESUMEN

This study objectives to evaluate the fracture strength of upper central incisors (UCI) restored with composite resin (CR) in Class III cavities and endodontically treated teeth with or without glass fiber post (GFP), analyzing their failure mode. Sixty human UCI were randomly divided into four experimental groups: endodontically treated teeth without GFP (G1), endodontically treated teeth with GFP (G2), teeth with mesial/distal Class III cavities restored with CR without GFP (G3), and teeth with mesial/distal Class III cavities restored with CR with GFP (G4). The samples were submitted to the fracture strength test in a universal testing machine with a compression shear load applied at speed of 1.0 mm/min until fracture occurred. The data were submitted to one-way ANOVA (α=0.05) and the samples were analyzed for failure mode. The analysis did not show a significant statistical difference in fracture strength between the groups (p>0.05). The results showed that only endodontically treated teeth (G1) (753.4N) presented behavior similar to teeth with GFP (G2) (702.1N). The same occurred when comparing teeth with Class III cavities without GFP (G3) (670.2 N) and with GFP (G4) (746.1N). It can be concluded that glass fiber posts do not change the fracture strength of incisors with endodontic treatment and Class III cavities.


Este estudo objetiva avaliar a resistência à fratura de incisivos centrais superiores (ICS) restaurados com resina composta (RC) em cavidades Classe III e dentes tratados endodonticamente com ou sem pino de fibra de vidro (PFV), analisando seu padrão de fratura. Sessenta ICS humanos foram divididos aleatoriamente em quatro grupos experimentais: dentes tratados endodonticamente sem PFV (G1), dentes tratados endodonticamente com PFV (G2), dentes com cavidades mesiais/distais Classe III restauradas com RC sem PFV (G3), e dentes com cavidades mesiais/distais Classe III restauradas com RC com PFV (G4). As amostras foram submetidas ao teste de resistência à fratura em uma máquina universal de ensaios com uma carga de cisalhamento de compressão aplicada na velocidade de 1,0 mm / min até a ocorrência da fratura. Os dados foram submetidos à ANOVA unidirecional (α=0,05) e as amostras foram analisadas quanto ao modo de falha. A análise não mostrou diferença estatisticamente significativa na resistência à fratura entre os grupos (p>0,05). Os resultados mostraram que os dentes apenas tratados endodonticamente (G1) (753,4N) apresentaram comportamento semelhante aos dentes com PFV (G2) (702,1N). O mesmo ocorreu ao comparar dentes com cavidades Classe III sem PFV (G3) (670.2 N) e com PFV (G4) (746.1N). Pode-se concluir que pinos de fibra de vidro não alteram a resistência à fratura de incisivos com tratamento endodôntico e cavidades Classe III.


Asunto(s)
Resinas Compuestas , Endodoncia , Resistencia Flexional
3.
RFO UPF ; 25(1): 42-49, 20200430. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1357721

RESUMEN

Purpose: evaluate the antimicrobial activity of intracanal dressings and their influence on dentinal colour changes. Material and methods: eighty single-rooted human extracted teeth were decoronated and divided into eight groups (n=10) according to intracanal dressing protocols inserted into the root canals: G1­distilled water (DW); G2­2% chlorhexidine gel (CHX); G3­calcium hydroxide (Ca[OH]2)+DW; G4­grape seed extract (GSE)+DW; G5­ginger extract (GE)+DW; G6­Ca(OH)2+CHX; G7­GSE+CHX; and G8­GE+CHX. The antimicrobial activity was evaluated by colony-forming units (CFUs) counting and dentinal colour changes was evaluated by digital spectrophotometry. Data were statistically analysed by One-way ANOVA followed by Tukey´s post hoc test (antimicrobial evaluation) and non-parametric Wilcoxon followed by the Mann- Whitney-U test (colour change evaluation) (α=0.05). Results: the highest bacterial reduction was observed in groups 4, 6, 7 and 8, with no significant difference between them (p<0.05). Groups 4 and 7 showed the highest medians of dentinal colour change (p<0.05). Conclusion: the addition of CHX improved the antimicrobial activity of GE-based intracanal dressing, with no effect in GSE-based intracanal dressing; moreover, these protocols induced significant dentinal colour changes. (AU)


Objetivo: avaliar a atividade antimicrobiana de medicações intracanais e sua influência na alteração da cor dentinária. Materiais e métodos: oitenta dentes humanos extraídos unirradiculares foram seccionados e divididos em oito grupos (n = 10), de acordo com os protocolos de medicação intracanal inseridos nos canais radiculares: água destilada G1 (DW); G2-2% de gel de clorexidina (CHX); hidróxido de cálcio G3 ­ (Ca [OH] 2) + DW; extrato de semente de uva G4 (GSE) + DW; extrato de gengibre G5 (GE) + DW; G6- Ca (OH) 2 + CHX; G7 ­ GSE + CHX; e G8-GE + CHX. A atividade antimicrobiana foi avaliada por contagem de unidades formadoras de colônias (UFCs) e as alterações de cor dentinária foram avaliadas por espectrofotometria digital. Os dados foram analisados estatisticamente por ANOVA one-way, seguida pelo teste post hoc de Tukey (avaliação antimicrobiana) e Wilcoxon não paramétrico, seguido pelo teste de Mann- Whitney-U (avaliação da mudança de cor) (α = 0,05). Resultados: a maior redução bacteriana foi observada nos grupos 4, 6, 7 e 8, sem diferença significativa entre eles (p < 0,05). Os grupos 4 e 7 apresentaram as maiores medianas da alteração da cor dentinária (p < 0,05). Conclusão: a adição de CHX melhorou a atividade antimicrobiana da medicação intracanal baseado em GE, sem efeito na medicação intracanal baseado em GSE; além disso, esses protocolos induziram alterações significativas na cor dentinária.(AU)


Asunto(s)
Humanos , Irrigantes del Conducto Radicular/farmacología , Irrigantes del Conducto Radicular/química , Extractos Vegetales/química , Clorhexidina/farmacología , Clorhexidina/química , Enterococcus faecalis/efectos de los fármacos , Dentina/efectos de los fármacos , Espectrofotometría/métodos , Hidróxido de Calcio/química , Recuento de Colonia Microbiana , Análisis de Varianza , Color , Estadísticas no Paramétricas , Zingiber officinale/química , Dentina/química , Extracto de Semillas de Uva/química
4.
Braz. dent. j ; 29(5): 459-464, Sept.-Oct. 2018. tab
Artículo en Inglés | LILACS | ID: biblio-974175

RESUMEN

Abstract The aim of this study was to compare the efficacy of grape seed extract (GSE), calcium hypochlorite [Ca(ClO)2], and sodium hypochlorite (NaOCl) irrigant solutions with rotary or reciprocating instrumentation for disinfection of root canals inoculated with Enterococcus faecalis. The mesiobuccal root canals of mandibular molars were prepared and inoculated with Enterococcus faecalis for 21 days. The roots were then randomly divided into the following eight experimental groups (n=11) according to the instrumentation technique and disinfection protocol: ProTaper Next or Reciproc R25 with sodium chloride (control group), 6% NaOCl, 6% Ca(ClO)2, or 50% GSE used for irrigation during instrumentation. The antimicrobial activity was determined on the basis of a reduction in colony-forming units (CFUs) counted on bacterial samples collected before and after root canal instrumentation and expressed as a percentage of reduction. Data were evaluated by two-way ANOVA followed by Tukey HSD post-hoc tests (p<0.05). No significant differences were observed in bacterial reduction between the ProTaper Next and Reciproc R25 systems (p>0.05), regardless of the irrigant solution used. Furthermore, all active solutions (6% NaOCl, 50% GSE, and 6% Ca(ClO)2) showed similar potential to reduce bacterial counts (p>0.05) and were significantly more effective than sodium chloride (control) (p<0.05). The results suggest that the GSE and Ca(ClO)2 have potential clinical application as irrigant solutions in endodontic therapy since they present bactericidal efficacy against Enterococcus faecalis.


Resumo O objetivo deste estudo foi comparar a eficácia do extrato de semente de uva (ESU), hipoclorito de cálcio [Ca(ClO)2] e hipoclorito de sódio (NaOCl) como soluções irrigadores quando utilizadas com instrumentos reciprocantes e rotatórios para desinfecção de canais radiculares infectados com Enterococcus faecalis. Raízes mesio-vestibulares de molares inferiores foram preparados e inoculados com E. faecalis por 21 dias. As raízes foram aleatoriamente divididas em 8 grupos (n=11) de acordo com a técnica de instrumentação e protocolo de irrigação: ProTaper Next ou Reciproc R25 associados com soro fisiológico (grupo controle), Ca(ClO)2 6%, NaOCl 6% ou ESU 50%. A atividade antimicrobiana foi determinada pela redução do número de Unidades Formadoras de Colonias (UFCs) coletadas antes e após a instrumentação e expressas em porcentagens de redução. Os dados foram analisados estatisticamente pelos testes ANOVA seguido pelo teste complementar de Tukey HSD (p<0,05). Não foi encontrado diferença estatisticamente significante na redução bacteriana entre os sistemas ProTaper Next e Reciproc R25 (p>0.05), independente da solução irrigadora usada. Além disso, todas as soluções ativas (NaOCl, ESU e Ca(ClO)2) mostraram similar potencial em reduzir a quantidade de bactérias (p>0.05) e foram significativamente mais efetivas que o soro fisiológico (p<0.05). Pode-se concluir que o ESU e o Ca(ClO)2 apresentam potencial para aplicação clínica como irrigantes endodônticos uma vez que apresentaram efetividade antimicrobiana contra o E. faecalis.


Asunto(s)
Humanos , Irrigantes del Conducto Radicular/farmacología , Desinfección/métodos , Enterococcus faecalis/efectos de los fármacos , Antibacterianos/farmacología , Hipoclorito de Sodio/farmacología , Células Madre , Técnicas In Vitro , Compuestos de Calcio/farmacología , Resinas Compuestas/química , Instrumentos Dentales , Cavidad Pulpar/microbiología , Extracto de Semillas de Uva/farmacología , Diente Molar
5.
Braz. dent. j ; 27(2): 228-233, Mar.-Apr. 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-778325

RESUMEN

Abstract The aim of this study was to evaluate the bond strength of a composite resin to glass-fiber post (GFP) treated or not with phosphoric acid, silane coupling agent, and unfilled resin. GFPs were etched or not with 37% phosphoric acid and different surface coating applied: silane coupling agent, unfilled resin, or both. Composite resin blocks were built around a 4-mm height on the GFP. Unfilled resin (20 s) and composite resin (40 s) were light activated by a light-emitting diode unit. The specimens were stored in distilled water at 37 °C for 24 h. Microtensile bond test was performed using a mechanical testing machine until failure (n=10). The data were analyzed using two-way ANOVA followed by Student-Newman-Keuls' test (p<0.05). Failure modes were classified as adhesive, mixed, or cohesive failures. Additional specimens (n=3) were made to analyze the bonded interfaces by scanning electron microscopy. The statistical analysis showed the factor 'surface coating' was significant (p<0.05), whereas the factor 'HP etching' (p=0.131) and interaction between the factors (p=0.171) were not significant. The highest bond strength was found for the silane and unfilled resin group (p<0.05). A predominance of adhesive and cohesive failures was found. Differences regarding the homogeneity and thickness of the unfilled resin layer formed by different GFP surface treatments were observed. The application of silane and unfilled resin can improve the bond strength between GFP and resin composite.


Resumo O objetivo deste estudo foi avaliar o efeito resistência de união de uma resina composta para pinos de fibra de vidro (PFV) tratados ou não com ácido fosfórico, agente de união (silano) e adesivo. PFVs foram condicionados ou não com ácido fosfórico 37% e receberam aplicação de diferentes materiais: um agente de união, um adesivo, ou ambos. Blocos em resina composta foram construídos a 4 mm de altura no PFV. O adesivo (20 s) e a resina composta (40 s) foram fotoativado por um diodo emissor de luz. As amostras foram armazenadas em água destilada a 37 C por 24 h. O teste de microtração foi realizado em uma máquina de ensaio universal (n=10). Os dados foram analisados usando ANOVA dois fatores e teste de Student-Newman-Keuls (p<0,05). Os padrões de fratura foram classificados em falhas adesivas, mistas ou coesivas. Amostras adicionais (n=3) foram feitas para análise da interface de união em microscopia eletrônica de varredura. A análise estatística mostrou que o fator 'recobrimento da superfície' foi significante (p<0,05), enquanto que o fator 'ácido fosfórico' (p=0,131) e a interação entre os fatores (p=0.171) não foram significantes. A maior resistência da união foi encontrada para os grupos silano e adesivo (p<0,05). Uma predominância de falhas adesivas e coesivas foi encontrada. Foram observadas diferenças em relação à homogeneidade e espessura da camada adesiva formada sobre os PFV com os diferentes tratamentos de superfície. Aplicação de silano e adesivo pode melhorar a resistência de união entre PFV e resina composta.


Asunto(s)
Grabado Ácido Dental , Técnica de Perno Muñón , Microscopía Electrónica de Rastreo , Propiedades de Superficie
6.
RFO UPF ; 20(1): 64-68, jan.-abr. 2015. ilus, tab
Artículo en Portugués | LILACS-Express | LILACS | ID: lil-758382

RESUMEN

Objetivo: avaliar in vitro a eficácia de diferentes substâncias químicas auxiliares utilizadas para promover a descontaminação de cones de guta-percha, que estão contaminados com diferentes microorganismos. Materiais e método: cepas Enterococcus faecalis, Candida albicans e Staphylococcus aureus foram os microrganismos testados. Os 72 cones de guta-percha foram divididos em três grupos de 24 cones, e foram transferidas individualmente em três tubos, contendo 5 ml de cada suspensão bacteriana, durante 1 hora. Os 24 cones de guta-percha de cada estirpe bacteriana foram distribuídos aleatoriamente em seis grupos (n = 4), de acordo com a substância química auxiliar e com o tempo de descontaminação, como segue: G1 (DW) - água destilada; G2 (NaOCl) - hipoclorito de sódio a 2,5%; G3 (Ca (OCl) 2) - 2,5% de hipoclorito de cálcio; G4 (CHX) - clorexidina gel 2%; G5 (QMix) - QMix e G6 (GSE) - Extrato de Semente de Uva 6,5%, em quatro períodos de avaliação, que foram 30, 60, 90 e 120 segundos. Depois de protocolos de desinfecção das pontas de guta-percha, foram transferidos para tubos contendo 450 mL de solução salina estéril, homogeneizada e diluída. Alíquotas de 100 µl da solução e as diluições foram cultivadas em duplicado em placas de ágar contendo o sangue. Esse material foi incubado durante 48 horas a 37 °C de temperatura. Depois disso, a contagem do número de unidades formadoras de colônias (CFU / mL) foi realizada. Resultados: os grupos 2 (NaOCl), 3 (Ca (OCl) 2), 4 (CHX) e 5 (QMix) não apresentaram crescimento bacteriano de microrganismos testados em todos os períodos de observação, sendo estatisticamente diferente de todos os outros grupos (p <0,05). O Grupo 6 (GSE) mostrou a melhor atividade antimicrobiana contra albicans Enterococcus faecalis e Candida Staphylococcus aureus em relação ao grupo 1 (DW), sendo estatisticamente diferente (p <0,05). Conclusão: hipoclorito de sódio a 2,5%, 2,5% de hipoclorito de cálcio, 2% de gel de clorexidina e QMix podem ser uti-lizados como agentes eficazes na desinfecção rápida de cones de guta-percha contaminados após 30 segundos de utilização dessas substâncias.

7.
Full dent. sci ; 6(22): 277-281, mar. 2015. tab, ilus
Artículo en Portugués | LILACS | ID: lil-754395

RESUMEN

Este estudo teve como objetivo avaliar, in vitro, a capacidade de diferentes técnicas de obturação no preenchimento de canais laterais artificiais em dentes extraídos usando recurso de imagem. Trinta dentes humanos extraídos (unirradiculares) foram selecionados, a porção coronária foi removida e o comprimento de trabalho foi determinado 1 mm aquém do forame apical. Dois canais laterais foram criados, um no terço médio e um terço apical, em cada raiz. Após o preparo químico-mecânico utilizando técnica escalonada com limas manuais, os dentes foram divididos em 3 grupos (n=10) de acordo com a técnica de obturação utilizada: G1-condensação lateral; G2- técnica híbrida de Tagger e G3- técnica do cone único. Em todos os grupos foram utilizados cones de guta-percha e cimento à base de óxido de zinco e eugenol. Após sete dias de armazenamento, radiografias pós-operatórias foram realizadas e as imagens foram projetadas para avaliação da qualidade da obturação dos canais laterais. Os dados foram submetidos à análise estatística pelo teste de Kruskal Wallis com nível de significância de 5%. A técnica híbrida de Tagger preencheu 35% dos canais laterais simulados, seguida pela técnica da condensação lateral (30%) e pela técnica do cone único (25%). No entanto, a análise estatística não revelou nenhuma diferença significativa na capacidade para preencher os canais laterais entre os grupos (p> 0,05). Embora a técnica híbrida de Tagger associada ao cimento endodôntico tenha apresentado uma incidência maior de preenchimento de canais laterais, as outras técnicas também apresentaram capacidade de proporcionar o selamento dos canais laterais simulados...


The purpose of this study was to evaluate, in vitro, the ability of different filling techniques for filling simulated lateral canals in extracted teeth using image resource. Thirty extracted single-rooted human teeth were selected, the coronal portion was removed, and the working length was established 1 mm short of the foramen. Two lateral canals were created, one in the middle third and one at the apical third, in each root canal. After chemo-mechanical preparation by the manual instrumentation through step-back technique, the teeth were divided into 3 groups (n = 10) according to the filling technique used: G1 - lateral condensation; G2 - Tagger hybrid technique; G3 - single cone technique. In all groups gutta-percha cones and zinc oxide and eugenol-based sealer were used. After seven days of storage, postoperative radiographs were taken and the images were projected for evaluation of the quality of lateral canal filling. Data were submitted to statistical analysis by Kruskal Wallis test at 5% significance level. The results showed that Tagger hybrid technique filled 35% of simulated lateral canals, followed by lateral condensation (30%) and single cone technique (25%). However, statistical analysis revealed no statistically significant difference in the ability to fill lateral canals among the groups (p>0.05). Although the Tagger hybrid technique associated with endodontic sealer presented a higher incidence to fill lateral canals, the other techniques also had the ability to provide the sealing of lateral canals...


Asunto(s)
Humanos , Cavidad Pulpar , Cementos Dentales/química , Endodoncia/métodos , Resultado del Tratamiento , Radiografía Dental/instrumentación
8.
Full dent. sci ; 5(18): 292-297, abr. 2014. ilus, tab, graf
Artículo en Portugués | LILACS, BBO | ID: lil-716609

RESUMEN

A literatura sugere que a utilização de lubrificante poderia aumentar a estabilidade das conexões parafusadas. Este estudo avaliou a influência do uso de lubrificante líquido no torque de afrouxamento de parafusos protéticos em próteses mandibulares implantossuportadas sob diferentes níveis de adaptação. Foram criadas duas condições de adaptação (adaptação passiva e desajuste), confeccionando 2 modelos de gesso a partir de cada prótese. Foram utilizados 20 conjuntos de parafusos protéticos de titânio (5 parafusos cada conjunto) divididos aleatoriamente em 4 grupos: 1) sem lubrificante + adaptação passiva (grupo controle); 2) sem lubrificante + esajuste; 3) com lubrificante + adaptação passiva e 4) com lubrificante + desajuste. O torque de afrouxamento dos parafusos foi mensurado 10 minutos após aplicação do torque de aperto (10 Ncm), utilizando torquímetro digital. Os resultados foram submetidos à ANOVA (2 fatores) e teste de Tukey (a=0,05). Os valores médios (desvio padrão) de torque de afrouxamento (Ncm) foram: G1 = 7,6 (0,4); G2 = 6,6 (0,3); G3 = 7,5 (0,2) e G4 = 6,9 (0,8). O fator ‘adaptação’ apresentou diferença estatisticamente significante (p=0,003). Porém, o fator ‘lubrificante’ e a interação entre os fatores não foram significantes (p=0,537 e p=0,311, respectivamente). O desajuste diminuiu o torque de afrouxamento dos parafusos protéticos, enquanto que o lubrificante líquido não apresentou efeito considerável.


The literature suggests that the use of lubricant may increase the screw joint stability. This study has evaluated the influence of the use of liquid lubricant on loosening torque of prosthetic screws in implant-supported mandibular dentures under different fit levels. Two conditions were created (passive fit and misfit) making 2 cast models from each denture. Twenty set of titanium prosthetic screws (5 screws each set) were randomly divided in 4 groups: 1) without lubricant + passive fit (control group); 2) without lubricant + misfit; 3) with lubricant + passive fit; and 4) with lubricant + misfit. The loosening torque of the screws was measured 10 minutes after applied torque (10 Ncm) using digital torque meter. The data were submitted to the ANOVA (two-way) and Tukey’s test (a;=0.05). The mean values (standard deviation) of loosening torque (Ncm) were: G1 = 7.6 (0.4); G2 = 6.6 (0.3); G3 = 7.5 (0.2); and G4 = 6.9 (0.8). The factor ‘fit’ presented significant statistically difference (p=0.003). However, the factor ‘lubricant’ and the factors interaction were not significant (p=0.537 and p=0.311, respectively). The misfit decreased the loosening torque of the prosthetic screws, whereas the liquid lubricant did not present considerable effect


Asunto(s)
Tornillos Óseos , Implantes Dentales , Técnicas In Vitro , Prótesis Dental , Torque
9.
Full dent. sci ; 4(15): 497-499, June 18, 2013. tab
Artículo en Portugués | LILACS, BBO | ID: biblio-850885

RESUMEN

O objetivo deste estudo foi avaliar a eficácia de solventes tradicionalmente utilizados (Hipoclorito de sódio – controle, Xilol e Eucaliptol) sobre obturadores de canais radiculares baseados em diferentes composições (óxido de zinco e eugenol, metacrilato (dois cimentos) e resina epóxica). Trinta amostras de cada material obturador foram divididas de maneira randomizada em três grupos (n=10), armazenadas por duas semanas em uma estufa para a secagem e imersas por 10 minutos em 1,0 ml de solvente. As amostras foram lavadas por 1 minuto em água corrente e novamente levadas à estufa por duas semanas. A perda da massa foi calculada com uma balança de precisão e os resultados submetidos à ANOVA dois fatores e ao teste Tukey com significância de 5%. Os resultados demonstraram que o tipo de material obturador não apresentou correlação à perda da massa (p> 0,05). Entretanto, o xilol teve um potencial de dissolução significante em relação aos solventes (p<0,05). Em relação aos materiais avaliados, pode-se concluir que os materiais obturadores não apresentam diferença no seu potencial de dissolução e que o xilol é o solvente mais eficaz


This study aimed to evaluate the efficacy of commonly utilised solvents (sodium hypochlorite - control, xylol and eucalyptol) on sealers based in different compositions (zincoxide-eugenol, methacrylate (two cements) and epoxy resin). Thirty samples of each cement were randomly divided in 3 groups (n=10), stored for 2 weeks in a chamber to set, immersed for 10 minutes in 1.0 mL of the solvent, washed for 1 minute in distilled water and stored in a new chamber for 2 weeks. The mass loss was calculated with a precision scale and the data subjected to 2-way ANOVA and Tukey’s test at 5% significance level. The results showed that the mass loss was not statistically significantly different among the sealers (p>0.05). However, the xylol potential was significantly higher among the solvents (p<0.05). Regarding the materials evaluated, it can be concluded that the sealers have no difference in their solving potential and xylol is the most effective solvent


Asunto(s)
Cavidad Pulpar , Disolución , Hipoclorito de Sodio/efectos adversos , Solventes/química , Tratamiento del Conducto Radicular/métodos , Análisis de Varianza , Endodoncia/métodos
10.
Dent. press endod ; 3(1): 84-87, 2013. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-688939

RESUMEN

Objetivo: avaliar a resposta do teste de sensibilidade ao frio em dentes que apresentam perda de estrutura por lesões cervicais não cariosas. Métodos: foram selecionados 18 pacientes atendidos nas disciplinas de Clínica Integrada da Faculdade de Odontologia da Universidade de Passo Fundo. Desses pacientes, foram analisados quarenta dentes monorradiculares (caninos e pré-molares) que preencheram os critérios de inclusão, sendo divididos em dois grupos: G1, composto por 20 dentes portadores de lesões cervicais não cariosas; G2 (controle), composto por 20 dentes sem perda de estrutura. Os pacientes foram orientados em relação ao nível de dor, seguindo uma escala visual analógica que classificava a resposta dolorosa em leve, moderada e severa. A partir das informações obtidas, os dados foram analisados estatisticamente pelo teste não-paramétrico de Kolmogorov-Smirnov ao nível de significância de 5%. Resultados: os resultados do presente estudo não demonstraram diferença estatisticamente significativa entre os dois grupos testados no que diz respeito à resposta aos testes de vitalidade pulpar (p < 0,05). Conclusão: de acordo com as limitações do presente estudo, foi concluído que os dentes com lesões cervicais não cariosas apresentaram diferentes níveis de respostas aos testes, o que sugere que dentes com perda de estrutura por essas lesões podem ou não apresentar sensibilidade pulpar.


Asunto(s)
Humanos , Pulpa Dental , Sensibilidad de la Dentina , Estadísticas no Paramétricas , Abrasión de los Dientes , Erosión de los Dientes , Prueba de la Pulpa Dental/métodos
11.
Artículo en Inglés | IMSEAR | ID: sea-145793

RESUMEN

Aims and Objectives: to evaluate the resistance to displacement of metal intraradicular retainers of different lengths by means of the shear test. Material and Methods: Thirty-six maxillary central incisors were cross-sectioned at 16 mm from the root apex, endodontically treated and randomly divided into three groups that were treated as follows: G1 (control) preparation of 2/3 (10.6 mm) of the total root length; G2: preparation of 1/2 (8 mm) of the total root length and G3: preparation of 1/3 (5.3 mm) of the total root length. After canal preparation, a matrix was made of the coronal and radicular portions using Duralay to obtain metal intraradicular retainers. These retainers were cemented with zinc phosphate cement and subjected to the compression shear test in a Universal Test Machine (EMIC DL 2000) at a crosshead speed of 0.5 mm/minute. The results were subjected to statistical analysis by analysis of variance (ANOVA) and Newman- Keuls, which showed statistically significant difference (P < 0.01). Results: The means in Newtons and their respective standard deviations were: G1 = 972.05 (±81.36); G2 = 921.15 (±112.25); G3 = 686.66 (±113.02). Conclusion: It could be concluded that metal retainers of 2/3 and 1/2 the length of the root portion showed higher resistance to displacement values when compared with the group that had been prepared for 1/3 of the root length.


Asunto(s)
Aleaciones Dentales/química , Recubrimiento Dental Adhesivo , Retención de Prótesis Dentales , Humanos , Incisivo/terapia , Ensayo de Materiales , Retenedores Ortodóncicos , Técnica de Perno Muñón , Preparación del Conducto Radicular , Tratamiento del Conducto Radicular , Diente no Vital/terapia , Raíz del Diente/anatomía & histología
12.
Rev. odonto ciênc ; 27(1): 64-68, 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-625038

RESUMEN

PURPOSE: To evaluate the ability of different endodontic systems to fill simulated lateral canals using resources of digital radiography. METHODS: Seventy extracted single-rooted human teeth were selected, the coronal access was performed, and the working length was established 1 mm short of the foramen. Two lateral canals were created, one in the middle third and one at the apical third, in each root canal. After chemo-mechanical preparation the teeth were divided into 7 groups (n=10) according to the filling material used: G1 Epiphany, G2 AH Plus, G3 EndoRez, G4 EndoFill, G5 Endomethasone, G6 Sealapex and G7 Sealer 26. In the G1 Epiphany system, Resilon cones were used. In all other groups gutta-percha cones were used. After seven days of storage, digital radiographs were taken to assess the results. The program DBSWIN measured the total length, in mm, of each lateral canal and the length, in mm, that each filling system was able to obturate the canals. Data were analyzed by ANOVA and Tukey's test at the 5% significance level. RESULTS: The filling system Sealer 26/gutta-percha showed less capacity to fill lateral canals than the other filling systems tested (P<0.05); statistical analysis revealed no statistically significant difference in the ability to fill lateral canals between the other groups (P>0.05). CONCLUSION: The system Sealer 26/gutta-percha was less effective in the filling of simulated lateral canals.


OBJETIVO: Avaliar a capacidade de obturação de canais laterais de diferentes sistemas obturadores endodônticos por meio de radiografia digital. METODOLOGIA: Setenta dentes humanos unirradiculares extraídos foram selecionados, a abertura coronária foi feita e o comprimento de trabalho foi determinado 1 mm aquém do forame apical. Foram confeccionados dois canais laterais, um no terço médio e outro no terço apical, em cada canal radicular. Após o preparo químico-mecânico os dentes foram divididos em 7 grupos (n=10) de acordo com o material obturador utilizado: G1, Epiphany; G2, AH Plus; G3, EndoRez; G4, EndoFill; G5, Endomethasone; G6, Sealapex; G7, Sealer 26. No G1 foram utilizados cones de Resilon e nos demais grupos cones de guta-percha. Sete dias após a obturação foram feitas radiografias digitais e as imagens foram introduzidas num software para a leitura dos resultados. Para avaliar a obturação dos canais laterais, o software mensurou em mm a extensão total de cada canal lateral e o quanto em mm cada sistema obturador conseguiu preencher em cada um deles. Os dados foram analisados estaticamente por ANOVA e teste de Tukey ao nível de significância de 5%. RESULTADOS: O sistema obturador Sealer 26/guta-percha obturou uma menor quantidade de canais laterais comparado aos demais sistemas obturadores em uma diferença estatisticamente significante (P<0,05); não houve diferença estatisticamente significante entre os demais grupos (P>0,05). CONCLUSÃO: O sistema obturador Sealer 26/guta-percha apresentou uma menor efetividade na obturação de canais laterais simulados.


Asunto(s)
Humanos , Masculino , Femenino , Técnicas In Vitro , Materiales Dentales , Obturación del Conducto Radicular , Radiografía Dental Digital
13.
Rev. odonto ciênc ; 27(3): 208-212, 2012. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: lil-656786

RESUMEN

PURPOSE: To evaluate the ability sealing of glass ionomer and composite resin with or without 1-mm thickness of Coltosol on the root-canal filling material. METHODS: Root-canal treatment was completed on 50-extracted human mandibular unirradicular. The teeth were divided into six groups: G1, positive control; G2, negative control; G3, glass ionomer (Vidrion R); G4, Coltosol + Vidrion R; G5, composite resin; and, G6, Coltosol + composite resin. For G1 and G2 five teeth each were used and for the other groups, ten teeth each. The teeth were thermocycled and evaluated for microleakage using methylene blue dye. Specimens were sectioned and measurements made to the maximum point of dye penetration. The mean dye penetration (%) for each group was compared by ANOVA and Tukey's test for post-hoc comparisons (α=0.05). RESULTS: The means and standard deviations of microleakage were: G1, 96.56 (±2.31); G2, 0.00 (±0.00); G3, 68.76 (±24.63); G4, 24.42 (±8.33); G5, 20.06 (±9.35); and, G6, 12.86 (±6.08). CONCLUSION: It was concluded that none of the materials were able to prevent microleakage. Composite resin alone or combined with coltosol and glass ionomer associated with coltosol resulted in less microleakage than the glass ionomer used alone.


OBJETIVOS: Avaliar a capacidade de selamento do ionomero de vidro e resina composta, com ou sem 1 mm de coltosol, sobre o material obturador endodôntico. MÉTODOS: O tratamento endodôntico foi realizado em 50 dentes humanos mandibulares unirradiculares. Os dentes foram divididos em 6 grupos: G1, controle positivo; G2, controle negativo; G3, ionômero de vidro (Vidrion R); G4, Coltosol + Vidrion R; G5, resina composta; e, G6, Coltosol + resina composta. Os dentes foram submetidos a termociclagem e a avaliação da microinfiltração usando azul de metileno. Os especimes foram seccionados e a quantidade maxima de penetração de corante avaliado. As medias e desvios-padrão de penetração do corante (em %) para cada grupo foram analisadas pelo teste ANOVA e pelo teste de multiplas comparações de Tukey's (α=0.05). RESULTADOS: As medias e desvios-padrão de midroinfiltração foram: G1: 96,56 (±2,31); G2: 0,00 (±0,00); G3: 68,76 (±24,63); G4: 24,42 (±8,33); G5: 20,06 (±9,35); and,G6: 12,86 (±6,08). CONCLUSÃO: Pode-se concluir que nenhum material obturador preveniu completamente a microinfiltração. Resina composta utilizada isoladamente ou associada ao coltosol e o ionômero de vidro associado ao coltosol apresentaram menor microinfiltração do que o ionomero de vidro utilizado sozinho.


Asunto(s)
Humanos , Masculino , Femenino , Cementos de Ionómero Vítreo , Materiales de Obturación del Conducto Radicular , Resinas Compuestas
14.
Rev. odonto ciênc ; 26(4): 341-345, 2011. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: lil-625019

RESUMEN

PURPOSE: To evaluate the bond strength of a total-etching adhesive system to dentin irrigated with 1% sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid 17% (EDTA). METHODS: Thirty human molars were sectioned 3mm below the oclusal surface and were randomly divided into 3 groups (n=10): G1, no treatment (control); G2, 1% NaOCl; G3, NaOCl followed by EDTA. The specimens received the total-etching adhesive system, restored with microhybrid composite resin, sectioned and trimmed to create 4 hourglass-shaped slabs of each tooth. The slabs were tested in microtensile bond strength in a universal testing machine (Emic DL 2000) at a crosshead speed of 0.5 mm/min until fracture. The results were analyzed statistically by ANOVA and Newman-Keuls test. G2 samples were not submitted to the test because they fractured just before testing, and its values were considered zero to the statistical analysis. RESULTS: The means and standard deviations (MPa) were: G1, 8.41 (±3.51); G2, 0.0 (±0.00); G3, 8.47 (±3.53). CONCLUSION: It was concluded that the application of the NaOCl irrigating solution significantly decreased the bond strength values. The use of NaOCl followed by EDTA resulted in bond strength values not statistically different from control group.


OBJETIVO: Avaliar a resistência de união de um sistema adesivo condicione-e-lave à dentina irrigada com hipoclorito de sódio 1% (NaOCl) e ácido etilenodiaminotetracético 17% (EDTA). METODOLOGIA: Trinta molares humanos foram seccionados 3mm abaixo da superficie oclusal e aleatoriamente divididos em 3 grupos (n=10): G1 (controle), nenhum tratamento; G2, NaOCl; G3, NaOCl seguido por EDTA. Os especimes foram hibridizados com um sistema adesivo condicione-e-lave, foram restaurados com resino composta microhibrida e seccionados de forma a originar 4 amplulhetas de cada dente. As fatias foram submetidas ao teste de resistência de união à microtraçnao em máquina universal de ensaios (EMIC DL 2000) à uma velocidade de 0,5 mm/min até o momento da fratura. Os resultados foram analisados estatisticamente por ANOVA seguido por Newman-Keuls. As amostras do G2 não foram submetidas aos testes de resistência de união pois fraturaram antes dos testes, e seus valores foram considerados zero para análise estatística. RESULTADOS: A média e desvios-padrão foram (MPa): G1 - 8,41 (±3,51); G2 - 0,0 (±0,00); e G3 - 8,47 (±3,53). CONCLUSÃO: Pode-se concluir que a irrigação com NaOCl diminui significativamente os valores de resistência de união. O uso de NaOCl seguido por EDTA resultaram em valores de resistência de união sem diferença estatística com o grupo controle.


Asunto(s)
Humanos , Masculino , Femenino , Adhesivos , Dentina/fisiología , Hipoclorito de Sodio , Irrigantes del Conducto Radicular/uso terapéutico
15.
Dent. press endod ; 1(2): 40-44, 2011. ilus, graf
Artículo en Portugués | LILACS | ID: lil-685794

RESUMEN

Objetivo: avaliar a concentração e o método de armazenagem da solução de hipoclorito de sódio em consultórios odontológicos na cidade de Santa Cruz do Sul/RS.Métodos: foram coletadas 50 amostras da solução, onde,por meio da titulometria, foi analisada a concentração de cloro ativo. Além da coleta, foi realizado um questionário com o intuito de verificar o tipo de embalagem e da tampa em que se encontrava a solução de hipoclorito de sódio,bem como o local de armazenamento. Resultados:a análise dos resultados demonstrou que, das 50 amostras avaliadas, 38 tinham a concentração abaixo da indicada,3 apresentavam teor de cloro ativo acima do informado pelo profissional e apenas 9 tinham a concentração indicada.Quanto à embalagem em que as soluções de hipoclorito eram armazenadas, das 50 amostras coletadas,40 eram armazenadas em embalagens de plástico leitoso,6 em plástico âmbar, 3 em plástico transparente e 1 em vidro. Quanto ao tipo de tampa, 46 das soluções coletadas foram encontradas armazenadas em embalagens com tampa de rosca, e apenas 4 em embalagens com tampa de pressão. Além disso, das 50 soluções coletadas,43 eram armazenadas em armários, 6 em ambientes refrigerado se 1 foi encontrada em cima do balcão ao lado de uma estufa. Conclusão: a maioria das soluções de hipoclorito de sódio coletadas e analisadas apresentou uma porcentagem de cloro ativo inferior ao informado pelo profissional, eram armazenadas em embalagens de plástico leitoso com tampa de rosca, e mantidas à temperatura ambiente em armários


Asunto(s)
Compuestos Químicos , Endodoncia , Encuestas y Cuestionarios , Hipoclorito de Sodio , Volumetría/métodos
16.
Dent. press endod ; 1(1): 82-86, 2011. tab, ilus, graf
Artículo en Portugués | LILACS, BBO | ID: lil-685768

RESUMEN

Objetivo: verificar o nível de limpeza de limas endodônticas após seu uso no preparo de canais radiculares e sua influência no processo de esterilização. Métodos: 50 limas endodônticas foram divididas em duas amostras: a primeira amostra de 25 limas para análise em microscopia eletrônica de varredura (MEV) para verificação da limpeza; e outra de 25, para análise microbiológica nos meios Tioglicolato e BHI, após a esterilização. Resultados: as limas endodônticas apresentaram diferentes graus de sujidade em sua parte ativa na avaliação através da microscopia eletrônica de varredura; e, através dos testes microbiológicos,foi possível verificar que não houve crescimento bacteriano após a esterilização. Conclusão: apesar da presença significativa de sujidade nas limas endodônticas em sua parte ativa,essa sujidade não interferiu no processo de esterilização.


Objective: The aim of this study was to assess the levelof cleaning of endodontic files after its use in root canalspreparation and their influence on the sterilization process.Methods: Fifty files were divided into two groups:one group of 25 files for analysis in scanning electron microscopy(SEM) for verification of cleaning and anothergroup of 25 files for microbiological analysis in thioglycolateand BHI after sterilization. Results: The resultsshowed that endodontic files had different degrees of dirton his active part through evaluation by scanning electronmicroscopy. The bacterial growth wasn’t detectedthrough microbiological test after sterilization. Conclusion:It was concluded that despite the significant presenceof dirt on endodontic files in their active part, thisdirt don’t interfere in the sterilization process.


Asunto(s)
Esterilización/métodos , Instrumentos Dentales , Materiales de Obturación del Conducto Radicular , Microscopía Electrónica de Rastreo
17.
J. appl. oral sci ; 18(4): 385-389, July-Aug. 2010. ilus, tab
Artículo en Inglés | LILACS | ID: lil-557109

RESUMEN

Chemical substances used during biomechanical preparation of root canals can alter the composition of dentin surface and affect the interaction with restorative materials. OBJECTIVE: The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a self-etching adhesive system to dentin irrigated with sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA). MATERIAL AND METHODS: Thirty human third molars were sectioned 3 mm below the occlusal surface, polished with 600- to 1200-grit silicon carbide papers, and randomly divided into 3 groups: G1 (control): no irrigating solution; G2: 1 percent NaOCl; and G3: 1 percent NaOCl followed by the application of 17 percent EDTA. The specimens received the self-etching adhesive system (XENO III - Dentsply), restored with microhybrid composite resin (Z250 - 3M ESPE), sectioned and trimmed to create 4 hourglass-shaped slabs of each tooth. The slabs were tested in microtensile strength in a universal testing machine (Emic DL 2000) at a crosshead speed of 0.5 mm/min until fracture. The results were analyzed statistically by ANOVA and Newman-Keuls test. RESULTS: Mean µTBS values and standard deviations in MPa were: G1 = 11.89 ± 4.22; G2 = 19.41 ± 5.32; G3 = 11.34 ± 4.73. 1 percent NaOCl increased the adhesive resistance significantly (p<0.001/F=22.5763). The application of 1 percent NaOCl/17 percent EDTA resulted in statistically similar µTBS to the control group. CONCLUSIONS: None of the irrigants affected negatively the µTBS of XENO III to dentin. The use of 1 percent NaOCl alone resulted in higher bond strength than the other treatments. The combination of 1 percent NaOCl and 17 percent EDTA produced similar bond strength to that of untreated dentin.


Asunto(s)
Humanos , Quelantes/química , Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios/química , Ácido Edético/química , Irrigantes del Conducto Radicular/química , Hipoclorito de Sodio/química , Adhesividad , Resinas Compuestas/química , Análisis del Estrés Dental/instrumentación , Dentina/ultraestructura , Ensayo de Materiales , Estrés Mecánico , Resistencia a la Tracción
18.
RFO UPF ; 15(1): 40-44, jan.-abr. 2010. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-874053

RESUMEN

O objetivo deste estudo foi avaliar a resistência de união à dentina de restaurações diretas e indiretas confeccionadas em resina composta por meio do ensaio de microtração. Trinta molares humanos hígidos tiveram suas superfícies oclusais seccionadas 2 mm abaixo das cúspides, obtendo-se superfícies planas de dentina. Os dentes foram divididos em dois grupos: G1 (restaurações indiretas), no qual a dentina foi isolada e os platôs confeccionados em resina composta foram deslocados, jateados com óxido de alimínio e posteriormente cimentados com sistema adesivo e cimento resinoso dual; G2 (restaurações diretas), no qual os platôs de resina foram confeccionados diretamente sobre a superfície dentinária com o mesmo sistema adesivo do G1. Os dentes foram seccionados, obtendo-se tres ampulhetas de cada dente (n=45/grupo). Os corpos-de-prova foram submetidos ao ensaio de microtração a 0,5mm/min. Os dados foram analisados estatísticamente pelo teste t Student (p>0,01). As médias e desvio padrão (MPa) foram: G1=22,02 (+ou- 12,47);G2=23,35 (+ou-9,82). Pode-se concluir que não houve diferença eststísticamente significativa na resistência de união à dentina de restaurações diretas e indiretas de resina composta


Asunto(s)
Humanos , Cementos Dentales , Resinas Sintéticas , Ciencia de los Materiales , Restauración Dental Permanente
19.
Braz. j. oral sci ; 9(1): 25-29, Jan.-Mar. 2010. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: lil-578042

RESUMEN

Aim: This study evaluated the influence of different chemomechanical caries removal techniqueson the bond strength of an adhesive system to caries-affected and healthy dentin. Methods:Thirty healthy teeth were randomly divided into three groups: Group 1 (control): no cariesremoval technique was applied; Group 2: chemomechanical technique using Carisolv®; andGroup 3: chemomechanical technique using Papacárie®Twenty caries-affected teeth were divided .into two groups: Group 4: chemomechanical technique using Carisolv; and Group 5:chemomechanical technique using Papacárie. The teeth received the application of an etch-andrinse adhesive system, were restored with composite resin, and then sectioned to obtain 4 hourglassshaped slabs from each specimen, which were subjected to a microtensile bond strength test. Datawere analyzed statistically by ANOVA and Tukey’s test (a=0.05). Results: G1 (13.387 ± 6.1074),G2 (18.123 ± 3.2611) and G3 (12.781 ± 4.5652) presented statistically significant higher meanbond strength values than the other groups (p<0.05), but did not differ significantly from each other(p>0.05). G4 (6.228 ± 5.3435) and G5 (6.482 ± 3.2076) presented the lowest mean bondstrength values and were statistically similar to each other (p>0.05). Conclusions: Neither of thechemomechanical caries removal methods interfered in the resin-dentin bond strength. However,lower tensile bond strength was found to caries-affected dentin.


Asunto(s)
Humanos , Caries Dental/terapia , Recubrimientos Dentinarios/química , Dentina/efectos de los fármacos , Ácido Glutámico/farmacología , Técnicas In Vitro , Leucina/farmacología , Lisina/farmacología , Papaína/farmacología , Grabado Ácido Dental , Análisis de Varianza , Resinas Acrílicas/química , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo
20.
Rev. clín. pesq. odontol. (Impr.) ; 5(3): 255-261, set.-dez. 2009. tab
Artículo en Portugués | LILACS, BBO | ID: lil-617424

RESUMEN

OBJETIVO: O objetivo deste estudo foi avaliar e comparar in vitro propriedades fisicas e mecanicas (resistencias a compressao e a tracao diametral, tempo de presa, fidelidade de copia e dureza) de gessos comerciais, cujas composicoes foram alteradas. MATERIAL E METODO: Foram confeccionados 40 corpos-de-prova para cada tipo de gesso e submetidos aos testes citados (n=10). Os corpos-de-prova obtidos para verificacao da resistencia a tracao foram antes submetidos a analise de dureza. Os tempos de presa foram analisados imediatamente apos a manipulacao dos materiais e os demais ensaios propostos foram realizados apos 7 dias da obtencao das amostras. RESULTADOS: Os valores obtidos nos testes foram analisados estatisticamente (1-way ANOVA, Tukey, p<0.05); observou-se que Exp1 apresentou melhor reproducao de detalhes e Exp2 o menor tempo de presa em relacao aos materiais comerciais (p<0.05). Nas demais propriedades, os gessos experimentais apresentaram comportamentos semelhantes aos comerciais. CONCLUSOES: Concluiu-se que as alteracoes na composicao dos gessos contribuiram para a melhoria na reproducao de detalhes no grupo Exp1, e diminuicao no tempo de presa no grupo Exp2.


OBJECTIVE: The purpose of this study was to evaluate and to compare in vitro mechanical and physical properties (compression and diametral tensile strength, setting time, loyalty to copy and hardness) of commercial and experimental gypsums (Exp1 and Exp2), whose compositions were altered. MATERIAL AND METHOD: Forty specimens were obtained for each type of gypsum (n=10). The specimens obtained to verify tensile strength were submitted to hardness analysis before. The setting time were analysed immediately after the manipulation of materials and the other tests were conducted 7 days after the specimens were obtained. RESULTS: The values were analyzed statistically (1-way ANOVA, Tukey, p <0.05) and it was observed that Exp1 showed better reproduction of details and Exp2 presented lesser setting time than commercial materials (p <0.05). As regards to other properties, experimental gypsums showed similar behavior to commercial gypsums. CONCLUSION: It was concluded that alterations in gypsum composition contributed to the improvement in reproduction of details in Exp1 group, and promoted a decrease in setting time in Exp2.


Asunto(s)
Materiales de Impresión Dental/química , Sulfato de Calcio/química , Dureza , Ensayo de Materiales , Reproducibilidad de los Resultados , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA